5V DC 10A SUB- MINIATURE RELAY
Subminiature relay with low profile package and lightweight, suited for a wide range of consumer equipment, industrial machines & automotive applications.
Application : Domestic Appliances, Office Machines, AudioEquipment, Coffee-Pots, Control units, etc.
FEATURES:
- RW Series Relay covers switching capacity by 10A is spite of miniature size to comply with user’s wide selection.
- RWH is approved C-UL & TÜV safety standard.
- The employment of suitable plastic materials is applied under high temperature condition and various chemical solutions.
- Complete protective construction is designed form dust and soldering flux. The plastic sealed type is available for washing procedure.
- 12A at 120VAC for RW & 12A at 240VAC for RWH are UL approved.
SPECIFICATIONS:
- Nominal Load (Resistive Load Cosφ=1)
- Contact Capacity:
- RW
- 12A at 120VAC.(UL)
- 10A at 120VAC.
- 10A at 24VDC.
- RWH
- 12A at 250VAC.(UL)
- 10A at 277VAC(TUV)
- TV-5 at 120VDC.
- 15A at 24VDC.
- Rated Carrying Current……..RW: 10A & RWH: 15A.
- Max. Allowable Current …….RW: 10A & RWH: 15A.
- Max. Allowable Voltage ……..AC 240V, DC 110V.
- Max. Allowable Power Force.
- RW: 1500 VA, 240W.
- RWH: 1800VA, 360W.
- Min. Switching Load
- RW: DC 5V, 10mA.
- RWH: DC5V, 15mA.
- Contact Material
- RW: Ag Alloy.
- RWH: AgSnO2.
- Contact Form……………………..SPST & SPDT.
- Contact Resistance ……………..100mΩ Max.@1A,6VDC
- Operate Time……………………..10 mSec. Max.
- Release Time ………………………5 mSec. Max.
- Dielectric Strength :
- Between Coil & Contact……..1,000VAC at 50/60 Hz for one minute.
- Between Contacts ………………500VAC at 50/60 Hz for one minute.
- Surge Resistance …………………3,000V (betweenCoil & Contact 1.2×50μSec.)
- Insulation Resistance…………..100 MegaΩ Min. at 500VDC.
- Max. On/Off Switching :
- Electrical……………………………. 30 Ops per Minute.
- Mechanical………………………… 300 Ops per Minute.
- Temperature Range ……………. -30 – 55°C
- Humidity Range………………… 45 – 85% RH.
- Coil Temperature Rise………… 35°C Max.
- Vibration :
- Endurance …………………………. 10 to 55 Hz dual amplitude width 1.5mm.
- Error Operation …………………. 10 to 55 Hz dual amplitude width 1.5mm.
- Shock :
- Endurance ……………………….. 1,000 m/S2 Min.
- Error Operation …………………. 100 m/S2 Min.
- Life Expectancy :
- Mechanical ………………………. 100,000,000 Operations at No Load condition.
Electrical ………………………….. 1,000,000 Operations at Rated Resistive Load.
- Mechanical ………………………. 100,000,000 Operations at No Load condition.
- Weight………………………………. About 11 g.
- Safety Standard & Its File Number :
- RW:
- UL …………………………………….. E141060
- CSA…………………………………… LR76598
- RWH:
- C-UL…………………………………. E141060
- TÜV………………………………….. R9854380
- RW: